Openings in the fire barriers shall be protected with assemblies having a.
Elevator machine room requirements california.
2 27 3 1 5 all fire recall switches shall be pro vided with an illuminated visual signal to indicate when phase i emergency recall operation is in effect.
It is a two story b occupancy type v i think.
Indicates where standby power is connected to elevators the machine room ventilation or air conditioning shall be connected to the standby power source.
Machine rooms shall be kept reasonably clean.
Special access lifts section 3136 article 37.
Inclined elevators section 3134 article 35.
Elevator machine rooms and machinery spaces shall be enclosed with fire barriers constructed in accordance with section 707 or horizontal assemblies constructed in accordance with section 712 or both the fire resistance rating shall not be less than the required rating of the hoistway enclosure served by the machinery.
The elevator machine room elevator machinery space.
The thought behind this is once the circuit is shunted sprinkler activation can drip water over the breaker and return power to the elevator.
Anyone using the room should have enough room to remove replace inspect and maintain elevator equipment.
For example in california the ventilation system must keep the temperature below 104 degrees fahrenheit at all times.
Section 3009 special requirements for elevators in hospitals.
Screw column elevators section 3135 article 36.
The elevator is not part of the moe except for accessibility.
Provide a fused disconnect switch for each elevator in the control room located in a position based on local code and within sight of elevator equipment and arranged to be locked in the off position.
Department shall be provided with the means to manually initiate a phase i emergency recall of the occupant evacuation elevators in accordance with california code of regulations title 8 division 1.
Rack and pinion elevators section 3133 article 34.
As of now national codes standard and elevator codes do not indicate specific locations for the elevator shunt trip breaker.
Working out of 2009 ibc section 3006 4 requires the room to be a.
The room environment is also subject to regulations.
I have an elevator machine room that is not rated as a one hour fire barrier.
Control room must be of adequate size to provide clearances around and between equipment as required by code.
Passage to enclosed equipment installed within the elevator machine room to provide the ventilation required by section 3011 f 2 a.
By the elevator or in the hoistway or in an elevator machine room or a control space or a control room see 2 27 3 2 shall initiate phase i emergency recall operation.
Seismic requirements for elevators escalators and moving walks section 3137 article 38.
3 air conditioning load in the elevator room is required to be on the generator set ibc section 3003 1 4 venting.